Victron MultiPlus-II 2x 120V Inverter Charger
FREE SHIPPING
Ships within 24 hours - Nationwide delivery
NO TAX
Save on sales tax - Applied at checkout
Overview
The Victron MultiPlus-II 2x120V is an inverter and battery charger designed for North American 50A 120/240VAC split-phase systems. With a split-phase shore or generator source, it can accept and pass through both lines of a 120/240V supply for connected loads and charging.
If a single-phase 120V source is connected, AC input is accepted on L1 for pass-through and charging, and the unit combines L1 and L2 outputs so you have 120V available on each output line.
In inverter mode, output is 120V single phase. 240V loads are supported only when a split-phase 120/240V input source is present.
Key Features
- PowerControl for setting a maximum grid or generator current limit to help prevent overload.
- PowerAssist to supplement limited shore or generator power with battery power during short peak loads (available on L1 input).
- Two AC outputs, a main output with fast transfer, plus an auxiliary output that is live only when external AC is present.
- VE.Bus communication for configuration and system integration within the Victron ecosystem.
- Parallel and three-phase configuration support (system design and configuration dependent).
Split-phase pass-through
Accepts a 120/240V split-phase source and passes through both lines for loads and charging.
120V inverter mode for both legs
When inverting from the battery, L1 and L2 are connected internally so both sides of a split-phase panel can receive 120V.
Auxiliary output for non-battery loads
The second AC output is intended for loads that should run only when external AC is available.
Technical Specs
| Spec | Details |
|---|---|
| Transfer switch | 50 A |
| Maximum AC input current | 50 A each leg |
| Inverter output voltage | 120 VAC plus or minus 2 percent |
| Frequency | 60 Hz plus or minus 0.1 percent, adjustable to 50 Hz |
| Continuous output power at 25 C | 3000 VA, 2400 W |
| Continuous output power at 40 C | 2200 W |
| Continuous output power at 65 C | 1700 W |
| Peak power | 5500 W |
| Auxiliary output | Live only when external AC is present, rated 50 A each leg |
| External AC current sensor | Optional, 100 A |
| Operating temperature range | -40 to +65 C, fan assisted cooling |
| Protection category | IP22 |
| Enclosure | Steel, blue RAL 5012 |
| 120/240 VAC connection | Screw terminals 21 mm2 (4 AWG) |
| Dimensions (H x W x D) | 578 x 275 x 148 mm (23 x 11 x 6 inch) |
| Weight | 22 kg (48 lb) |
| Safety standard | UL 458, EN-IEC 60335-1, EN-IEC 60335-2-29 |
12V Specs
| Spec | Details |
|---|---|
| Model | 12/3000/120-50 |
| DC input voltage range | 9.5 to 17 V |
| Maximum efficiency | 93 percent |
| Maximum battery charge current | 120 A |
| Charger AC input | Split phase 180 to 280 VAC, single phase 90 to 140 VAC, 45 to 65 Hz |
24V Specs
| Spec | Details |
|---|---|
| Model | 24/3000/70-50 |
| DC input voltage range | 19 to 33 V |
| Maximum efficiency | 94 percent |
| Maximum battery charge current | 70 A |
| Charger AC input | Split phase 180 to 280 VAC, single phase 90 to 140 VAC, 45 to 65 Hz |
Resources and Downloads
Frequently Asked Questions (click to expand)
No. In inverter mode the output is 120V single phase. 240V loads are supported only when a split-phase 120/240V input source is present.
The unit can supply both L1 and L2 sides of a typical split-phase panel with 120V. With external split-phase power present, it can pass through both lines of 120/240V to loads.
AC input is accepted on L1 for pass-through and charging, and the unit combines L1 and L2 outputs so you have 120V available on each output line.
AC-out-1 is the main output for loads. AC-out-2 is an auxiliary output that is live only when external AC is present, intended for loads you do not want to run from the battery.
Yes. PowerControl allows a maximum input current to be set. PowerAssist can supplement short peak loads with battery power (available on L1 input).
This product family includes 12V and 24V models. Choose the variant that matches your battery bank voltage.
Victron documents parallel and three-phase configuration support. System design and configuration determine what is possible and what additional components may be required.
No. The auxiliary output switches off when no external AC source is available.
Shop The Full Collection
What Our Customers Say
Trusted by 5000+ Happy Homeowners
John M.
Texas
"This zero-turn mower cut my mowing time in half! The 50% discount made it an incredible deal. Highly recommend S3Stores!"
Product: Zero-Turn Mower
Sarah K.
Florida
"Best purchase ever! The Husqvarna arrived quickly and was easy to assemble. My lawn has never looked better."
Product: Husqvarna Mower
Mike R.
Ohio
"Amazing customer service and unbeatable prices. Got my Cub Cadet at half price - couldn't be happier!"
Product: Cub Cadet
David L.
Georgia
"Professional quality at residential prices. The financing options made it easy to upgrade my equipment."
Product: Professional Mower
Jennifer S.
Tennessee
"Fast shipping, great communication. My new Ariens handles like a dream. Worth every penny!"
Product: Ariens Mower
Robert T.
Alabama
"S3Stores made buying a mower so easy. The team helped me choose the perfect model for my 2-acre lot."
Product: Riding Mower
Brands We Trust
Authorized Dealer of Industry-Leading Outdoor Power Equipment