{"product_id":"multiplus-ii-2x120v","title":"Victron MultiPlus-II 2x 120V Inverter Charger","description":"\u003ch2\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h2\u003e \u003cp\u003eThe Victron MultiPlus-II 2x120V is an inverter and battery charger designed for North American 50A 120\/240VAC split-phase systems. With a split-phase shore or generator source, it can accept and pass through both lines of a 120\/240V supply for connected loads and charging.\u003c\/p\u003e \u003cp\u003eIf a single-phase 120V source is connected, AC input is accepted on L1 for pass-through and charging, and the unit combines L1 and L2 outputs so you have 120V available on each output line.\u003c\/p\u003e \u003cdiv class=\"important-info\"\u003e \u003cdiv class=\"important-info__title\"\u003eImportant Info\u003c\/div\u003e \u003cp\u003eIn inverter mode, output is 120V single phase. 240V loads are supported only when a split-phase 120\/240V input source is present.\u003c\/p\u003e \u003c\/div\u003e \u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e \u003cul\u003e \u003cli\u003ePowerControl for setting a maximum grid or generator current limit to help prevent overload.\u003c\/li\u003e \u003cli\u003ePowerAssist to supplement limited shore or generator power with battery power during short peak loads (available on L1 input).\u003c\/li\u003e \u003cli\u003eTwo AC outputs, a main output with fast transfer, plus an auxiliary output that is live only when external AC is present.\u003c\/li\u003e \u003cli\u003eVE.Bus communication for configuration and system integration within the Victron ecosystem.\u003c\/li\u003e \u003cli\u003eParallel and three-phase configuration support (system design and configuration dependent).\u003cbr\u003e\u003cbr\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003cdiv class=\"highlight-box\"\u003e \u003ch3 class=\"highlight-box__title\"\u003eSplit-phase pass-through\u003c\/h3\u003e \u003cp\u003eAccepts a 120\/240V split-phase source and passes through both lines for loads and charging.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"highlight-box\"\u003e \u003ch3 class=\"highlight-box__title\"\u003e120V inverter mode for both legs\u003c\/h3\u003e \u003cp\u003eWhen inverting from the battery, L1 and L2 are connected internally so both sides of a split-phase panel can receive 120V.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"highlight-box\"\u003e \u003ch3 class=\"highlight-box__title\"\u003eAuxiliary output for non-battery loads\u003c\/h3\u003e \u003cp\u003eThe second AC output is intended for loads that should run only when external AC is available.\u003c\/p\u003e \u003c\/div\u003e \u003ch3 class=\"specs-title\"\u003eTechnical Specs\u003c\/h3\u003e \u003ctable class=\"dist-table-hover\" style=\"width: 100.089%;\"\u003e \u003cthead\u003e \u003ctr\u003e \u003cth style=\"width: 40.9842%;\"\u003eSpec\u003c\/th\u003e \u003cth style=\"width: 58.6561%;\"\u003eDetails\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"width: 40.9842%;\"\u003eTransfer switch\u003c\/td\u003e \u003ctd style=\"width: 58.6561%;\"\u003e50 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"width: 40.9842%;\"\u003eMaximum AC input current\u003c\/td\u003e \u003ctd style=\"width: 58.6561%;\"\u003e50 A each leg\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"width: 40.9842%;\"\u003eInverter output voltage\u003c\/td\u003e \u003ctd style=\"width: 58.6561%;\"\u003e120 VAC plus or minus 2 percent\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"width: 40.9842%;\"\u003eFrequency\u003c\/td\u003e \u003ctd style=\"width: 58.6561%;\"\u003e60 Hz plus or minus 0.1 percent, adjustable to 50 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"width: 40.9842%;\"\u003eContinuous output power at 25 C\u003c\/td\u003e \u003ctd style=\"width: 58.6561%;\"\u003e3000 VA, 2400 W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"width: 40.9842%;\"\u003eContinuous output power at 40 C\u003c\/td\u003e \u003ctd style=\"width: 58.6561%;\"\u003e2200 W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"width: 40.9842%;\"\u003eContinuous output power at 65 C\u003c\/td\u003e \u003ctd style=\"width: 58.6561%;\"\u003e1700 W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"width: 40.9842%;\"\u003ePeak power\u003c\/td\u003e \u003ctd style=\"width: 58.6561%;\"\u003e5500 W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"width: 40.9842%;\"\u003eAuxiliary output\u003c\/td\u003e \u003ctd style=\"width: 58.6561%;\"\u003eLive only when external AC is present, rated 50 A each leg\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"width: 40.9842%;\"\u003eExternal AC current sensor\u003c\/td\u003e \u003ctd style=\"width: 58.6561%;\"\u003eOptional, 100 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"width: 40.9842%;\"\u003eOperating temperature range\u003c\/td\u003e \u003ctd style=\"width: 58.6561%;\"\u003e-40 to +65 C, fan assisted cooling\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"width: 40.9842%;\"\u003eProtection category\u003c\/td\u003e \u003ctd style=\"width: 58.6561%;\"\u003eIP22\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"width: 40.9842%;\"\u003eEnclosure\u003c\/td\u003e \u003ctd style=\"width: 58.6561%;\"\u003eSteel, blue RAL 5012\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"width: 40.9842%;\"\u003e120\/240 VAC connection\u003c\/td\u003e \u003ctd style=\"width: 58.6561%;\"\u003eScrew terminals 21 mm2 (4 AWG)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"width: 40.9842%;\"\u003eDimensions (H x W x D)\u003c\/td\u003e \u003ctd style=\"width: 58.6561%;\"\u003e578 x 275 x 148 mm (23 x 11 x 6 inch)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"width: 40.9842%;\"\u003eWeight\u003c\/td\u003e \u003ctd style=\"width: 58.6561%;\"\u003e22 kg (48 lb)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"width: 40.9842%;\"\u003eSafety standard\u003c\/td\u003e \u003ctd style=\"width: 58.6561%;\"\u003eUL 458, EN-IEC 60335-1, EN-IEC 60335-2-29\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch4 class=\"specs-title\"\u003e12V Specs\u003c\/h4\u003e \u003ctable class=\"dist-table-hover\"\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eSpec\u003c\/th\u003e \u003cth\u003eDetails\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eModel\u003c\/td\u003e \u003ctd\u003e12\/3000\/120-50\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC input voltage range\u003c\/td\u003e \u003ctd\u003e9.5 to 17 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMaximum efficiency\u003c\/td\u003e \u003ctd\u003e93 percent\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMaximum battery charge current\u003c\/td\u003e \u003ctd\u003e120 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCharger AC input\u003c\/td\u003e \u003ctd\u003eSplit phase 180 to 280 VAC, single phase 90 to 140 VAC, 45 to 65 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch4 class=\"specs-title\"\u003e24V Specs\u003c\/h4\u003e \u003ctable class=\"dist-table-hover\"\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003eSpec\u003c\/th\u003e \u003cth\u003eDetails\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eModel\u003c\/td\u003e \u003ctd\u003e24\/3000\/70-50\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC input voltage range\u003c\/td\u003e \u003ctd\u003e19 to 33 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMaximum efficiency\u003c\/td\u003e \u003ctd\u003e94 percent\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMaximum battery charge current\u003c\/td\u003e \u003ctd\u003e70 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCharger AC input\u003c\/td\u003e \u003ctd\u003eSplit phase 180 to 280 VAC, single phase 90 to 140 VAC, 45 to 65 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch2\u003e\u003cstrong\u003eResources and Downloads\u003c\/strong\u003e\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Datasheet-MultiPlus-II-3kVA-2x120V-EN.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cstrong\u003eDatasheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/MultiPlus-II_2x120V\/32424-MultiPlus-II___Quattro-II-pdf-en.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cstrong\u003eManual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003ch2\u003e\u003cstrong\u003eFrequently Asked Questions (click to expand)\u003c\/strong\u003e\u003c\/h2\u003e \u003cdiv class=\"faq-item\"\u003e \u003cdiv class=\"question\"\u003e \u003cspan\u003e1.\u003c\/span\u003e Does it provide 240V when running from the battery?\u003c\/div\u003e \u003cdiv class=\"answer\"\u003e \u003cp\u003eNo. In inverter mode the output is 120V single phase. 240V loads are supported only when a split-phase 120\/240V input source is present.\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003cdiv class=\"question\"\u003e \u003cspan\u003e2.\u003c\/span\u003e What does 2x120V mean for a split-phase panel?\u003c\/div\u003e \u003cdiv class=\"answer\"\u003e \u003cp\u003eThe unit can supply both L1 and L2 sides of a typical split-phase panel with 120V. With external split-phase power present, it can pass through both lines of 120\/240V to loads.\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003cdiv class=\"question\"\u003e \u003cspan\u003e3.\u003c\/span\u003e What happens if I only have a single-phase 120V hookup?\u003c\/div\u003e \u003cdiv class=\"answer\"\u003e \u003cp\u003eAC input is accepted on L1 for pass-through and charging, and the unit combines L1 and L2 outputs so you have 120V available on each output line.\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003cdiv class=\"question\"\u003e \u003cspan\u003e4.\u003c\/span\u003e What are the two AC outputs used for?\u003c\/div\u003e \u003cdiv class=\"answer\"\u003e \u003cp\u003eAC-out-1 is the main output for loads. AC-out-2 is an auxiliary output that is live only when external AC is present, intended for loads you do not want to run from the battery.\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003cdiv class=\"question\"\u003e \u003cspan\u003e5.\u003c\/span\u003e Can I limit shore or generator current?\u003c\/div\u003e \u003cdiv class=\"answer\"\u003e \u003cp\u003eYes. PowerControl allows a maximum input current to be set. PowerAssist can supplement short peak loads with battery power (available on L1 input).\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003cdiv class=\"question\"\u003e \u003cspan\u003e6.\u003c\/span\u003e Which battery voltages are supported?\u003c\/div\u003e \u003cdiv class=\"answer\"\u003e \u003cp\u003eThis product family includes 12V and 24V models. Choose the variant that matches your battery bank voltage.\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003cdiv class=\"question\"\u003e \u003cspan\u003e7.\u003c\/span\u003e Can I expand the system later?\u003c\/div\u003e \u003cdiv class=\"answer\"\u003e \u003cp\u003eVictron documents parallel and three-phase configuration support. System design and configuration determine what is possible and what additional components may be required.\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003cdiv class=\"question\"\u003e \u003cspan\u003e8.\u003c\/span\u003e Is AC-out-2 available when there is no external AC source?\u003c\/div\u003e \u003cdiv class=\"answer\"\u003e \u003cp\u003eNo. The auxiliary output switches off when no external AC source is available.\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"Victron Energy","offers":[{"title":"12V \/ 3000VA\/ 120-50 \/ UL Certified","offer_id":44618413113447,"sku":"ART-PMP122305102-VIC","price":2000.0,"currency_code":"USD","in_stock":true},{"title":"24V \/ 3000VA\/ 70-50 \/ UL Certified","offer_id":44618413146215,"sku":"ART-PMP242305132-VIC","price":2000.0,"currency_code":"USD","in_stock":true},{"title":"24V \/ 3000VA\/ 70-50 \/ Not UL Certified","offer_id":44618413178983,"sku":"ART-PMP242305130-VIC","price":2000.0,"currency_code":"USD","in_stock":true},{"title":"12V \/ 4000VA \/ 160-50 \/ Not UL Certified","offer_id":44618413211751,"sku":"ART-PMP122405200-VIC","price":2000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0691\/5191\/6135\/files\/PMP122305100__20MultiPlus-II_2012_3000_120-50_2x120V_20_28front_29nw.webp?v=1789422450","url":"https:\/\/orionvangear.store\/products\/multiplus-ii-2x120v","provider":"orionvangear.store","version":"1.0","type":"link"}